Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21.579
Filtrar
1.
PLoS One ; 19(4): e0299025, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640102

RESUMO

BACKGROUND: The evaluation of surveillance systems has been recommended by the World Health Organization (WHO) to identify the performance and areas for improvement. Universal salt iodization (USI) as one of the surveillance systems in Tanzania needs periodic evaluation for its optimal function. This study aimed at evaluating the universal salt iodization (USI) surveillance system in Tanzania from January to December 2021 to find out if the system meets its intended objectives by evaluating its attributes as this was the first evaluation of the USI surveillance system since its establishment in 2010. The USI surveillance system is key for monitoring the performance towards the attainment of universal salt iodization (90%). METHODOLOGY: This evaluation was guided by the Center for Disease Control Guidelines for Evaluating Public Health Surveillance Systems, (MMWR) to evaluate USI 2021 data. The study was conducted in Kigoma region in March 2022. Both Purposive and Convenient sampling was used to select the region, district, and ward for the study. The study involved reviewing documents used in the USI system and interviewing the key informants in the USI program. Data analysis was done by Microsoft Excel and presented in tables and graphs. RESULTS: A total of 1715 salt samples were collected in the year 2021 with 279 (16%) of non-iodized salt identified. The majority of the system attributes 66.7% had a good performance with a score of three, 22.2% had a moderate performance with a score of two and one attribute with poor performance with a score of one. Data quality, completeness and sensitivity were 100%, acceptability 91.6%, simplicity 83% were able to collect data on a single sample in < 2 minutes, the system stability in terms of performance was >75% and the usefulness of the system had poor performance. CONCLUSION: Although the system attributes were found to be working overall well, for proper surveillance of the USI system, the core attributes need to be strengthened. Key variables that measure the system performance must be included from the primary data source and well-integrated with the Local Government (district and regions) to Ministry of Health information systems.


Assuntos
Iodo , Tanzânia/epidemiologia , Iodo/análise , Cloreto de Sódio na Dieta/análise
2.
Am J Clin Nutr ; 119(4): 927-948, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38569787

RESUMO

BACKGROUND: A global move toward consumption of diets from sustainable sources is required to protect planetary health. As this dietary transition will result in greater reliance on plant-based protein sources, the impact on micronutrient (MN) intakes and status is unknown. OBJECTIVE: Evaluate the evidence of effects on intakes and status of selected MNs resulting from changes in dietary intakes to reduce environmental impact. Selected MNs of public health concern were vitamins A, D, and B12, folate, calcium, iron, iodine, and zinc. METHODS: We systematically searched 7 databases from January 2011 to October 2022 and followed the PRISMA guidelines. Eligible studies had to report individual MN intake and/or status data collected in free-living individuals from the year 2000 onward and environmental outcomes. RESULTS: From the 10,965 studies identified, 56 studies were included, mostly from high-income countries (n = 49). Iron (all 56) and iodine (n = 20) were the most and least reported MNs, respectively. There was one randomized controlled trial (RCT) that also provided the only biomarker data, 10 dietary intake studies, and 45 dietary modeling studies, including 29 diet optimization studies. Most studies sought to reduce greenhouse gas emissions or intake of animal-sourced foods. Most results suggested that intakes of zinc, calcium, iodine, and vitamins B12, A, and D would decrease, and total iron and folate would increase in a dietary transition to reduce environmental impacts. Risk of inadequate intakes of zinc, calcium, vitamins A, B12 and D were more likely to increase in the 10 studies that reported nutrient adequacy. Diet optimization (n = 29) demonstrated that meeting nutritional and environmental targets is technically feasible, although acceptability is not guaranteed. CONCLUSIONS: Lower intakes and status of MNs of public health concern are a potential outcome of dietary changes to reduce environmental impacts. Adequate consideration of context and nutritional requirements is required to develop evidence-based recommendations. This study was registered prospectively with PROSPERO (CRD42021239713).


Assuntos
Iodo , Micronutrientes , Humanos , Cálcio , Cálcio da Dieta , Dieta , Ácido Fólico , Ferro , Vitaminas , Zinco , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
J Texture Stud ; 55(2): e12833, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38634383

RESUMO

Videofluoroscopic swallowing study (VFSS), alongside flexible endoscopic evaluation of swallowing, represents the gold standard for diagnosing swallowing disorders and to determine severity, pathophysiology, and effective interventions, including texture modification. The clinical swallowing examination and assessment supplements these instrumental methods and serves as the basis for the modules of swallowing diagnostics. The adaptation of food and drink consistencies in dysphagia management has become widespread. For valid results of a VFSS with respect to confirming swallowing safety and efficiency of different liquid and food consistencies and textures, the use of uniform recipes containing radio-opaque contrast media is important. Our goal was to identify recipes that would produce consistencies that conform to the liquid and food levels of 0-7, as defined by the International Dysphagia Diet Standardization Initiative (IDDSI), with barium- and iodine-based contrast media, xanthan gum-based thickeners, and other edible components, which also show sufficient contrast on VFSS. In this study, we determined the different recipes using IDDSI testing methods and explored their radiological characteristics using a Philips MultiDiagnost Eleva fluoroscopy system and two different fluid contrast agents: barium- (Micropaque®) and iodine-based (Telebrix®). All recipes showed sufficient contrast on fluoroscopy and could be visualized in the amounts used for swallowing examinations. They were practical and easy to implement in terms of production and availability of the components. The homogeneity of the recipes diminished with higher IDDSI levels, which represent transitional food, but appeared still sufficient for fluoroscopic examination. The opacity did not significantly differ between the barium- and iodine-based contrast media.


Assuntos
Transtornos de Deglutição , Iodo , Humanos , Transtornos de Deglutição/diagnóstico , Meios de Contraste , Bário , Viscosidade
4.
Int J Mol Sci ; 25(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38612798

RESUMO

Brassica vegetables are widely consumed all over the world, especially in North America, Asia, and Europe. They are a rich source of sulfur compounds, such as glucosinolates (GLSs) and isothiocyanates (ITCs), which provide health benefits but are also suspected of having a goitrogenic effect. Adhering to PRISMA guidelines, we conducted a systematic review to assess the impact of dietary interventions on thyroid function, in terms of the potential risk for people with thyroid dysfunctions. We analyzed the results of 123 articles of in vitro, animal, and human studies, describing the impact of brassica plants and extracts on thyroid mass and histology, blood levels of TSH, T3, T4, iodine uptake, and the effect on thyroid cancer cells. We also presented the mechanisms of the goitrogenic potential of GLSs and ITCs, the limitations of the studies included, as well as further research directions. The vast majority of the results cast doubt on previous assumptions claiming that brassica plants have antithyroid effects in humans. Instead, they indicate that including brassica vegetables in the daily diet, particularly when accompanied by adequate iodine intake, poses no adverse effects on thyroid function.


Assuntos
Brassica , Bócio , Iodo , Animais , Humanos , Verduras , Isotiocianatos , Glucosinolatos
5.
Nutrients ; 16(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38613074

RESUMO

The influence of iodine-rich foods on thyroid cancer (TC) risk remains inadequately understood. Therefore, we aimed to comprehensively investigate the relationship between three iodine-rich food groups and TC prevalence using extensive data from a large Korean population. We assessed the dietary intake of 169,057 participants in the Korean Genome and Epidemiology Study (2004-2013) using a food frequency questionnaire. The top-three iodine-rich food groups (including egg, seaweed, and dairy) were selected based on Korean dietary reference intakes and categorized by weekly consumption frequency. We conducted multiple logistic regression models to examine the relationship between food consumption and TC prevalence. After adjusting for confounding factors, higher seaweed consumption (>5 times/week) was significantly associated with lower TC prevalence (odds ratio [OR], 95% confidence interval [CI] = 0.42, 0.32-0.56, p-value < 0.001). In contrast, compared with moderate dairy consumption (3-4 times/week), lower dairy product intake (<1 time/week) was associated with higher TC prevalence (OR, 95% CI = 1.32, 1.05-1.67, p-value = 0.017). Our findings suggest that sufficient seaweed consumption may offer protection against TC, and incorporating dairy products into the diet may lower TC incidence in the Korean population. The most significant limitations of our study are the absence of 24 h urine samples for iodine status assessment and the lack of clinical data on the diagnosis of thyroid cancer.


Assuntos
Iodo , Alga Marinha , Neoplasias da Glândula Tireoide , Humanos , Neoplasias da Glândula Tireoide/epidemiologia , Neoplasias da Glândula Tireoide/etiologia , Povo Asiático , Razão de Chances
6.
Top Curr Chem (Cham) ; 382(2): 12, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589598

RESUMO

Organoselenium compounds have been the subject of extensive research since the discovery of the biologically active compound ebselen. Ebselen has recently been found to show activity against the main protease of the virus responsible for COVID-19. Other organoselenium compounds are also well-known for their diverse biological activities, with such compounds exhibiting interesting physical properties relevant to the fields of electronics, materials, and polymer chemistry. In addition, the incorporation of selenium into various organic molecules has garnered significant attention due to the potential of selenium to enhance the biological activity of these molecules, particularly in conjunction with bioactive heterocycles. Iodine and iodine-based reagents play a prominent role in the synthesis of organoselenium compounds, being valued for their cost-effectiveness, non-toxicity, and ease of handling. These reagents efficiently selenylate a broad range of organic substrates, encompassing alkenes, alkynes, and cyclic, aromatic, and heterocyclic molecules. They serve as catalysts, additives, inducers, and oxidizing agents, facilitating the introduction of different functional groups at alternate positions in the molecules, thereby allowing for regioselective and stereoselective approaches. Specific iodine reagents and their combinations can be tailored to follow the desired reaction pathways. Here, we present a comprehensive review of the progress in the selenylation of organic molecules using iodine reagents over the past decade, with a focus on reaction patterns, solvent effects, heating, microwave, and ultrasonic conditions. Detailed discussions on mechanistic aspects, such as electrophilic, nucleophilic, radical, electrochemical, and ring expansion reactions via selenylation, multiselenylation, and difunctionalization, are included. The review also highlights the formation of various cyclic, heterocyclic, and heteroarenes resulting from the in situ generation of selenium intermediates, encompassing cyclic ketones, cyclic ethers, cyclic lactones, selenophenes, chromones, pyrazolines, pyrrolidines, piperidines, indolines, oxazolines, isooxazolines, lactones, dihydrofurans, and isoxazolidines. To enhance the reader's interest, the review is structured into different sections covering the selenylation of aliphatic sp2/sp carbon and cyclic sp2 carbon, and then is further subdivided into various heterocyclic molecules.


Assuntos
Iodo , Isoindóis , Compostos Organosselênicos , Selênio , Iodo/química , Indicadores e Reagentes , Compostos Organosselênicos/química , Lactonas/química , Carbono
7.
Biomed Environ Sci ; 37(3): 254-265, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38582990

RESUMO

Objective: Studies on the relationship between iodine, vitamin A (VA), and vitamin D (VD) and thyroid function are limited. This study aimed to analyze iodine and thyroid-stimulating hormone (TSH) status and their possible relationships with VA, VD, and other factors in postpartum women. Methods: A total of 1,311 mothers (896 lactating and 415 non-lactating) from Hebei, Zhejiang, and Guangxi provinces were included in this study. The urinary iodine concentration (UIC), TSH, VA, and VD were measured. Results: The median UIC of total and lactating participants were 142.00 µg/L and 139.95 µg/L, respectively. The median TSH, VA, and VD levels in all the participants were 1.89 mIU/L, 0.44 µg/mL, and 24.04 ng/mL, respectively. No differences in the UIC were found between lactating and non-lactating mothers. UIC and TSH levels were significantly different among the three provinces. The rural UIC was higher than the urban UIC. Obese mothers had a higher UIC and a higher prevalence of excessive TSH. Higher UICs and TSHs levels were observed in both the VD deficiency and insufficiency groups than in the VD-sufficient group. After adjustment, no linear correlation was observed between UIC and VA/VD. No interaction was found between vitamins A/D and UIC on TSH levels. Conclusion: The mothers in the present study had no iodine deficiency. Region, area type, BMI, and VD may be related to the iodine status or TSH levels.


Assuntos
Iodo , Tireotropina , Humanos , Feminino , Estudos Transversais , Lactação , China/epidemiologia , Período Pós-Parto , Estado Nutricional , Vitaminas , Vitamina D , Vitamina A , Colecalciferol
8.
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 43(2): 107-112, Mar-Abr. 2024. graf, tab
Artigo em Espanhol | IBECS | ID: ibc-231820

RESUMO

Introducción y objetivos: El tratamiento con yodo radiactivo (RAIT) se recomienda para reducir el riesgo de recurrencia y de metástasis en personas con cáncer diferenciado de tiroides (CDT) de riesgo intermedio-alto. En la preparación para la RAIT, la estimulación de la tirotropina y la reducción en la reserva corporal de yodo son elementos importantes para contribuir al éxito de la terapia. Para ello, se pide a los pacientes que reduzcan la ingesta de este mineral antes de la RAIT, y puede evaluarse su reserva corporal midiendo su excreción por la orina (yoduria) antes del tratamiento. El objetivo de nuestro estudio ha sido comparar los métodos utilizados para medir la reserva de yodo corporal en la evaluación de la eficacia de la dieta con bajo contenido en yodo (RID) aplicada a la preparación del paciente para la RAIT. Pacientes y métodos: Suspendieron la levotiroxina tres semanas antes de la RAIT y fueron controlados con una RID durante las dos semanas previas a la realización del tratamiento 80 pacientes con CDT. Tras dos semanas de RID, en todos se llevó a cabo una recolección de orina de 24h el día previo a la fecha de administración de la RAIT. Los sujetos finalizaron dicha recolección en la mañana de la fecha de RAIT y suministraron una muestra puntual de orina. Se calculó la excreción estimada de creatinina en orina de 24 horas de los pacientes. La estimación de la excreción urinaria de yodo o yoduria (UIE) de 24 horas oras se determinó a partir del índice yodo/creatinina (I/C) obtenido en la muestra de orina puntual de los individuos. Se compararon los resultados de la yoduria de 24 horas, la concentración de yodo en la muestra puntual de orina, el cociente I/C en la muestra puntual de orina y la estimación de la yoduria de 24 horas en los pacientes. Resultados: En 99%, la eficacia de la RID fue suficiente según la yoduria de 24 horas obtenida previamente a la RAIT...(AU)


Introduction and Objectives: Radioactive iodine therapy (RAIT) is recommended to reduce the risk of recurrence and metastasis in patients with intermediate-high risk differentiated thyroid cancer (DTC). In preparation for RAIT, stimulation of thyroid-stimulating hormone and reduction of body iodine pool are important for treatment success. For this purpose, patients are asked to reduce their iodine intake before RAIT, and the body iodine pool can be evaluated by measuring iodine excretion in urine before treatment. The aim of our study is to compare the methods used to measure the body iodine pool in the evaluation of the restricted iodine diet (RID) effectiveness applied in the RAIT preparation. Patients and methods: Eighty DTC patients discontinued levothyroxine three weeks before RAIT and followed up with a RID two weeks before treatment. After two weeks of RID, all patients collected their 24-hour urine the day before the RAIT date. Patients completed 24-hour urine samples on the morning of the RAIT date and also provided a spot urine sample. The estimated 24-hour creatinine excretion of the patients was calculated. Estimated 24-hour urinary iodine excretion (UIE) was calculated using the spot urine iodine/creatinine (I/C) ratio of the patients. 24-hour UIE, iodine concentration in spot urine, I/C ratios in spot urine and estimated 24-hour UIE of the patients were analyzed by comparing with each other. Results: In 99% of the patients, RID efficiency was sufficient according to 24-hour UIE before RAIT. The mean 24-hour UIE was 48.81 micrograms/day (mcg/day) in 24-hour urine samples taken from the patients to evaluate the body iodine pool. The patients’ iodine concentrations in spot urine, I/C ratios in spot urine, and estimated 24-hour UIE were all statistically significantly lower than actual 24-hour UIE, which was the reference method (p: 0.026 vs <0.001 vs 0.041)..... (AU)


Assuntos
Humanos , Neoplasias da Glândula Tireoide , Dieta , Iodo , Creatinina , Metástase Neoplásica , Recidiva Local de Neoplasia , Urinálise
9.
Sci Rep ; 14(1): 5310, 2024 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438474

RESUMO

Our study aimed to compare bone scintigraphy and dual-layer detector spectral CT (DLCT) with multiphase contrast enhancement for the diagnosis of osteoblastic bone lesions in patients with prostate cancer. The patients with prostate cancer and osteoblastic bone lesions detected on DLCT were divided into positive bone scintigraphy group (pBS) and negative bone scintigraphy group (nBS) based on bone scintigraphy. A total of 106 patients (57 nBS and 49 pBS) was included. The parameters of each lesion were measured from DLCT including Hounsfield unit (HU), 40-140 keV monochromatic HU, effective nuclear numbers (Zeff), and Iodine no water (InW) value in non-contrast phase (N), the arterial phase (A), and venous phase (V). The slope of the spectral curve at 40 and 100 keV, the different values of the parameters between A and N phase (A-N), V and N phase (V-N), and hybrid prediction model with multiparameters were used to differentiate pBS from nBS. Receiver operating characteristic analysis was performed to compare the area under the curve (AUC) for differentiating the pBS group from the nBS group. The value of conventional HU values, slope, and InW in A-N and V-N, and hybrid model were significantly higher in the pBS group than in the nBS group. The hybrid model of all significant parameters had the highest AUC of 0.988, with 95.5% sensitivity and 94.6% specificity. DLCT with arterial contrast enhancement phase has the potential to serve as an opportunistic screening tool for detecting positive osteoblastic bone lesions, corresponding to those identified in bone scintigraphy.


Assuntos
Doenças Ósseas , Doenças das Cartilagens , Iodo , Neoplasias da Próstata , Masculino , Humanos , Detecção Precoce de Câncer , Tomografia Computadorizada por Raios X , Programas de Rastreamento , Neoplasias da Próstata/diagnóstico por imagem , Cintilografia
10.
Zhonghua Yi Xue Za Zhi ; 104(10): 751-757, 2024 Mar 12.
Artigo em Chinês | MEDLINE | ID: mdl-38462355

RESUMO

Objective: To evaluate the application value of reducing tube voltage and iodine delivery rate according to body weight in coronary CT angiography (CCTA). Methods: A prospective randomized controlled study. A total of 297 subjects, 172 males and 125 females, aged [M (Q1, Q3)]60.0 (50.0, 68.0) years, who underwent CCTA examination in Peking University Third Hospital due to clinically suspected coronary heart disease from May to December 2022 were included. According to the odd or even visit dates, the subjects were randomly divided into test group (n=156) and control group (n=141). The subjects in both groups were divided into four sub-groups according to body weight: 50-59 group, 60-69 kg group, 70-79 kg group and 80-89 kg group, respectively. The CCTA images were reconstructed with hybrid iterative algorithm(KARL 3D) with levels of 6 and 8, respectively. 100 kVp and iodine flow rate 1.1, 1.3, 1.4 and 1.5 gI/s recommended by the domestic CCTA application guidelines were used in the control group, while the tube voltage and iodine flow rate were reduced in the test group based on the guidelines and body weight:70 kVp and 0.8 g I/s in 50~59 kg group, 80 kVp and 1.0 gI/s in 60~69 kg group, 80 kVp and 1.1 gI/s in70~79 kg group, and 100 kVp and 1.5 gI/s in 80~89 kg group, respectively. The CT values and standard deviation (SD) of aortic root, proximal left anterior descending branch (LAD) and distal right coronary artery (RCA) luminal CCTA, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of coronary artery CT images, subjective coronary scores and effective radiation dose (ED) were compared between the both groups. One-way ANOVA or Wilcoxon test was used to analyze the differences of above indicators between the groups to evaluate the application value of low voltage and low iodine flow rate based on weight in coronary CCTA. Results: CT values of aortic root, LAD proximal CT values and SD values of aortic root [411.4 (377.2, 439.8) HU, (366.3±42.9) HU, 26.5±2.3] in the test group were all higher than those in the control group [379.00 (335.2, 415.9) HU, (355.0±46.9) HU and 24.8±2.3]. The differences were statistically significant (all P<0.05), and the other parameters were not statistically significant (all P>0.05). The total subjective image quality score in test group were superior to those in the control group (all P<0.05). The total ED and contrast agent dosage [2.07 (1.52, 3.28) mSv and (38.28±9.68) ml] in CCTA examination in the test group were lower than those in the control group [3.30(2.32, 4.44) mSv and (45.31±5.63) ml], and the differences were statistically significant (all P<0.05). The dosage of ED and contrast agent in the test group was decreased by 37.3% and 15.5%, respectively. Conclusion: Combined with KARL 3D,it is feasible to reduce contrast medium and ED by setting the tube voltage and iodine flow rate of CCTA according to the weight of the subject, which can further reduce the radiation dose and contrast agent dosage of CCTA.


Assuntos
Angiografia por Tomografia Computadorizada , Iodo , Masculino , Feminino , Humanos , Idoso , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Estudos Prospectivos , Doses de Radiação , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Peso Corporal , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
11.
Phys Med ; 120: 103334, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38520889

RESUMO

PURPOSE: Contrast-enhanced digital mammography (CEDM) is a relatively new imaging technique recombining low- and high-energy mammograms to emphasise iodine contrast. This work aims to perform a multicentric physical and dosimetric characterisation of four state-of-the-art CEDM systems. METHODS: We evaluated tube output, half-value-layer (HVL) for low- and high-energy and average glandular dose (AGD) in a wide range of equivalent breast thicknesses. CIRS phantom 022 was used to estimate the overall performance of a CEDM examination in the subtracted image in terms of the iodine difference signal (S). To calculate dosimetric impact of CEDM examination, we collected 4542 acquisitions on patients. RESULTS: Even if CEDM acquisition strategies differ, all the systems presented a linear behaviour between S and iodine concentration. The curve fit slopes expressed in PV/mg/cm2 were in the range [92-97] for Fujifilm, [31-32] for GE Healthcare, [35-36] for Hologic, and [114-130] for IMS. Dosimetric data from patients were matched with AGD values calculated using equivalent PMMA thicknesses. Fujifilm exhibited the lowest values, while GE Healthcare showed the highest. CONCLUSION: The subtracted image showed the ability of all the systems to give important information about the linearity of the signal with the iodine concentrations. All the patient-collected doses were under the AGD EUREF 2D Acceptable limit, except for patients with thicknesses ≤35 mm belonging to GE Healthcare and Hologic, which were slightly over. This work demonstrates the importance of testing each CEDM system to know how it performs regarding dose and the relationship between PV and iodine concentration.


Assuntos
Neoplasias da Mama , Iodo , Humanos , Feminino , Intensificação de Imagem Radiográfica/métodos , Meios de Contraste , Mamografia/métodos , Mama , Imagens de Fantasmas
12.
Sci Rep ; 14(1): 6993, 2024 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-38523151

RESUMO

Iodine deficiency and excessive salt intake have adverse health effects. This study evaluated the iodine level and salt intake in Chinese adults aged 18-59 years after implementing the salt reduction program and compared with both the World Health Organization (WHO) and Chinese recommendations. Adults aged 18-59 years were randomly selected using multi-stage stratified random sampling in coastal urban area (CUA), non-coastal urban area (Non-CUA), coastal rural area (CRA), and non-coastal rural area (Non-CRA) of Fujian Province, China. Iodine, sodium, and creatinine concentrations in spot urine samples were measured. Knudsen equation was used to determine 24-h urinary iodine and sodium excretion. The median urinary iodine concentration (mUIC) and urinary sodium concentration (mUNaC) among adults (n = 3513) were 132.0 µg/L and 4.0 g/d, respectively. The mUIC and median daily iodine intake in CUA, Non-CUA, CRA and Non-CRA were 112.1, 127.5, 128.5, 167.5 µg/L and 189.6, 182.5, 199.4, 236.0 µg/d, respectively. The mUNaC and median daily salt intake (mDSI) in these four areas were 2.4, 2.8, 2.9, 2.9 g/L and 9.8, 10.4, 10.4, 10.6 g/d, respectively. The mUIC and DII of residents were higher in the Non-CRA than in the other three areas (P < 0.05). The UNaC and DSI of residents were lower in the CUA than in the other three areas (P < 0.05). The logistic regression demonstrated that the people living in CUA and Non-CUA consumed less salt compared with those in Non-CRA. Except for Non-CUA, the DII was lower (< 150 µg/d) among women of childbearing age in the low-salt intake group (< 5 g/d) compared with the high-salt intake group (≥ 5 g/d) (P < 0.05). Iodine nutrition in Chinese adults aged 18-59 years was sufficient, but the salt intake was substantially higher than the WHO and Chinese recommendations. Further policy implementation is needed to reduce salt intake and improve the monitoring of iodine levels in Chinese adults, especially in women of childbearing age.


Assuntos
Iodo , Cloreto de Sódio na Dieta , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , China , Iodo/urina , Estado Nutricional , Sódio/urina , Cloreto de Sódio na Dieta/efeitos adversos , Cloreto de Sódio na Dieta/análise
13.
Eur Thyroid J ; 13(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38471306

RESUMO

Global warming is now universally acknowledged as being responsible for dramatic climate changes with rising sea levels, unprecedented temperatures, resulting fires and threatened widespread species loss. While these effects are extremely damaging, threatening the future of life on our planet, one unexpected and paradoxically beneficial consequence could be a significant contribution to global iodine supply. Climate change and associated global warming are not the primary causes of increased iodine supply, which results from the reaction of ozone (O3) arising from both natural and anthropogenic pollution sources with iodide (I-) present in the oceans and in seaweeds (macro- and microalgae) in coastal waters, producing gaseous iodine (I2). The reaction serves as negative feedback, serving a dual purpose, both diminishing ozone pollution in the lower atmosphere and thereby increasing I2. The potential of this I2 to significantly contribute to human iodine intake is examined in the context of I2 released in a seaweed-abundant coastal area. The bioavailability of the generated I2 offers a long-term possibility of increasing global iodine status and thereby promoting thyroidal health. It is hoped that highlighting possible changes in iodine bioavailability might encourage the health community to address this issue.


Assuntos
Iodo , Ozônio , Alga Marinha , Humanos , Mudança Climática , Oceanos e Mares , Ozônio/análise , Atmosfera
14.
Curr Opin Clin Nutr Metab Care ; 27(3): 259-265, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38547335

RESUMO

PURPOSE OF REVIEW: To assess the most relevant articles on the impact of iodine supply in at-risk populations, namely infants and young children, pregnant and lactating women. RECENT FINDINGS: The 2022 Iodine Global Network Annual Report confirmed the dramatic decrease of severe iodine deficiency over the last 30 years, thanks to universal iodine iodization. However, mild to moderate deficiency is still present in many countries, where recent data showed a decrease of iodine intake and an impairment of iodine status. Unfortunately, there is yet no validated biomarker to classify the iodine status at the individual level. Available data show that there is no clear evidence to link mild-to-moderate iodine deficiency to adverse health outcomes in pregnant and lactating women as well as in infants and children. The description of a negative impact of maternal iodine excess on neurodevelopment of infants is of concern. SUMMARY: Optimization of salt iodization (e.g. careful increase in iodine concentration in salt, use by food industry in processed foods) combined with targeted, personalized supplementation under medical supervision if needed (e.g. low intake of iodine rich foods, vegan diet) seems currently preferable to blanket supplementation.


Assuntos
Iodo , Lactente , Gravidez , Criança , Humanos , Feminino , Pré-Escolar , Lactação , Estado Nutricional , Cloreto de Sódio na Dieta , Fatores de Risco
15.
Phys Med Biol ; 69(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38471186

RESUMO

Following the rapid, but independent, diffusion of x-ray spectral and phase-contrast systems, this work demonstrates the first combination of spectral and phase-contrast computed tomography (CT) obtained by using the edge-illumination technique and a CdTe small-pixel (62µm) spectral detector. A theoretical model is introduced, starting from a standard attenuation-based spectral decomposition and leading to spectral phase-contrast material decomposition. Each step of the model is followed by quantification of accuracy and sensitivity on experimental data of a test phantom containing different solutions with known concentrations. An example of a micro CT application (20µm voxel size) on an iodine-perfusedex vivomurine model is reported. The work demonstrates that spectral-phase contrast combines the advantages of spectral imaging, i.e. high-Zmaterial discrimination capability, and phase-contrast imaging, i.e. soft tissue sensitivity, yielding simultaneously mass density maps of water, calcium, and iodine with an accuracy of 1.1%, 3.5%, and 1.9% (root mean square errors), respectively. Results also show a 9-fold increase in the signal-to-noise ratio of the water channel when compared to standard spectral decomposition. The application to the murine model revealed the potential of the technique in the simultaneous 3D visualization of soft tissue, bone, and vasculature. While being implemented by using a broad spectrum (pink beam) at a synchrotron radiation facility (Elettra, Trieste, Italy), the proposed experimental setup can be readily translated to compact laboratory systems including conventional x-ray tubes.


Assuntos
Compostos de Cádmio , Iodo , Pontos Quânticos , Camundongos , Animais , Iluminação , Fótons , Telúrio , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
16.
Med Phys ; 51(4): 2871-2881, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38436473

RESUMO

BACKGROUND: Dual-energy CT (DECT) systems provide valuable material-specific information by simultaneously acquiring two spectral measurements, resulting in superior image quality and contrast-to-noise ratio (CNR) while reducing radiation exposure and contrast agent usage. The selection of DECT scan parameters, including x-ray tube settings and fluence, is critical for the stability of the reconstruction process and hence the overall image quality. PURPOSE: The goal of this study is to propose a systematic theoretical method for determining the optimal DECT parameters for minimal noise and maximum CNR in virtual monochromatic images (VMIs) for fixed subject size and total radiation dose. METHODS: The noise propagation in the process of projection based material estimation from DECT measurements is analyzed. The main components of the study are the mean pixel variances for the sinogram and monochromatic image and the CNR, which were shown to depend on the Jacobian matrix of the sinograms-to-DECT measurements map. Analytic estimates for the mean sinogram and monochromatic image pixel variances and the CNR as functions of tube potentials, fluence, and VMI energy are derived, and then used in a virtual phantom experiment as an objective function for optimizing the tube settings and VMI energy to minimize the image noise and maximize the CNR. RESULTS: It was shown that DECT measurements corresponding to kV settings that maximize the square of Jacobian determinant values over a domain of interest lead to improved stability of basis material reconstructions. Instances of non-uniqueness in DECT were addressed, focusing on scenarios where the Jacobian determinant becomes zero within the domain of interest despite significant spectral separation. The presence of non-uniqueness can lead to singular solutions during the inversion of sinograms-to-DECT measurements, underscoring the importance of considering uniqueness properties in parameter selection. Additionally, the optimal VMI energy and tube potentials for maximal CNR was determined. When the x-ray beam filter material was fixed at 2 mm of aluminum and the photon fluence for low and high kV scans were considered equal, the tube potential pair of 60/120 kV led to the maximal iodine CNR in the VMI at 53 keV. CONCLUSIONS: Optimizing DECT scan parameters to maximize the CNR can be done in a systematic way. Also, choosing the parameters that maximize the Jacobian determinant over the set of expected line integrals leads to more stable reconstructions due to the reduced amplification of the measurement noise. Since the values of the Jacobian determinant depend strongly on the imaging task, careful consideration of all of the relevant factors is needed when implementing the proposed framework.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Modelos Teóricos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
17.
Clin Endocrinol (Oxf) ; 100(5): 502-510, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38433726

RESUMO

OBJECTIVE: Iodine fortification (IF) induces an initial increase followed by a decrease in the incidence of hyperthyroidism in the general population. Within the population of hyperthyroid patients, the sex-, age- and subtype distribution changes after IF. The risk of atrial fibrillation (AF) in hyperthyroid patients may be influenced by these factors. Therefore, we aimed to examine how the association between incident hyperthyroidism and AF was affected by IF increasing the population iodine intake from moderate-mild iodine deficiency to low adequacy. DESIGN, PATIENTS AND MEASUREMENTS: Incident hyperthyroid patients were included at the date of first inpatient or outpatient diagnosis, and AF diagnoses within 3 months before to 6 months after the index date were identified in Danish nationwide registers, 1997-2018. The relative risk (RR) of AF each calendar year (reference: 1997; IF introduced: 2000) was analyzed in Poisson regression models adjusted for age, sex, educational level, geographic region, and comorbidities. RESULTS: Overall, in 62,201 patients with incident hyperthyroidism 7.9% were diagnosed with AF. There was a minor nonsignificantly increased risk of AF during the first years after IF followed by a gradual decrease to RR 0.76 (0.62-0.94) in 2017. There were no statistically significant differences in the development in the risk of AF by sex, age group, or geographic region. CONCLUSIONS: Results indicate that IF may reduce the risk of concomitant AF in hyperthyroid patients. If these results are confirmed, IF may not only reduce the population incidence of hyperthyroidism but also reduce the burden of morbidity in the remaining hyperthyroid patients.


Assuntos
Fibrilação Atrial , Hipertireoidismo , Iodo , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Hipertireoidismo/complicações , Hipertireoidismo/epidemiologia , Hipertireoidismo/diagnóstico , Comorbidade , Risco , Incidência , Fatores de Risco
18.
Tomography ; 10(3): 299-319, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38535766

RESUMO

Dual-energy CT (DECT) is an innovative technology that is increasingly widespread in clinical practice. DECT allows for tissue characterization beyond that of conventional CT as imaging is performed using different energy spectra that can help differentiate tissues based on their specific attenuation properties at different X-ray energies. The most employed post-processing applications of DECT include virtual monoenergetic images (VMIs), iodine density maps, virtual non-contrast images (VNC), and virtual non-calcium (VNCa) for bone marrow edema (BME) detection. The diverse array of images obtained through DECT acquisitions offers numerous benefits, including enhanced lesion detection and characterization, precise determination of material composition, decreased iodine dose, and reduced artifacts. These versatile applications play an increasingly significant role in tumor assessment and oncologic imaging, encompassing the diagnosis of primary tumors, local and metastatic staging, post-therapy evaluation, and complication management. This article provides a comprehensive review of the principal applications and post-processing techniques of DECT, with a specific focus on its utility in managing oncologic patients.


Assuntos
Artefatos , Iodo , Humanos , Tomografia Computadorizada por Raios X
19.
Med J Malaysia ; 79(Suppl 1): 8-13, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38555879

RESUMO

INTRODUCTION: Bismuth oxide (Bi2O3) particles gained attention in preclinical research especially in medical imaging. Bismuth oxide with its long circulation time is an alternative to the current iodine contrast media which directly possesses high X-ray attenuation coefficient. Exploration of bismuth compound is hampered owing to challenges in synthesizing control for in vivo stability. MATERIALS AND METHODS: This study aimed are to characterize Bi2O3 particles synthesized at 60, 90 and 120 °C via hydrothermal method and investigated cytotoxicity of cell viability assay, cell morphology analysis, intracellular reactive oxygen species (ROS) assay and expression of ER stress genes by real-time PCR. RESULTS: Results indicated that the size of rod-shaped Bi2O3 particles increased with rising synthesizing temperatures. The cytotoxicity of Bi2O3 particles in Chang liver cells was size-dependent. Bigger-sized Bi2O3 particles resulted in lesser toxicity effects. mRNA expressions of GRP78 and C/EBP homologous protein (CHOP) were down-regulated in all treated Chang liver cells due to the increasing size of Bi2O3 particles. Bi2O3 particles synthesized at 120 °C was found to be less toxic than iodine. CONCLUSION: Data suggested that the response of Chang liver cells to Bi2O3 particle cytotoxicity has a significant relationship with its reaction temperatures. This outcome is important in hazard assessment of Bi2O3 particles as a new contrast media and provides better understanding in synthesizing control to enhance its biocompatibility.


Assuntos
Bismuto , Iodo , Humanos , Bismuto/toxicidade , Meios de Contraste/toxicidade , Temperatura
20.
Spectrochim Acta A Mol Biomol Spectrosc ; 313: 124098, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38460232

RESUMO

L-Acetylcarnitine (ALC), a versatile compound, has demonstrated beneficial effects in depression, Alzheimer's disease, cognitive impairment, and other conditions. This study focuses on its antithyroid activity. The precursor molecule, L-carnitine, inhibited the uptake of triiodothyronine (T3) and thyroxine (T4), and it is possible that ALC may reduce the iodination process of T3 and T4. Currently, antithyroid drugs are used to control the excessive production of thyroid hormones (TH) through various mechanisms: (i) forming electron donor-acceptor complexes with molecular iodine, (ii) eliminating hydrogen peroxide, and (iii) inhibiting the enzyme thyroid peroxidase. To understand the pharmacological properties of ALC, we investigated its plausible mechanisms of action. ALC demonstrated the ability to capture iodine (Kc = 8.07 ± 0.32 x 105 M-1), inhibit the enzyme lactoperoxidase (LPO) (IC50 = 17.60 ± 0.76 µM), and scavenge H2O2 (39.82 ± 0.67 mM). A comprehensive physicochemical characterization of ALC was performed using FTIR, Raman, and UV-Vis spectroscopy, along with theoretical DFT calculations. The inhibition process was assessed through fluorescence spectroscopy and vibrational analysis. Docking and molecular dynamics simulations were carried out to predict the binding mode of ALC to LPO and to gain a better understanding into the inhibition process. Furthermore, albumin binding experiments were also conducted. These findings highlight the potential of ALC as a therapeutic agent, providing valuable insights for further investigating its role in the treatment of thyroid disorders.


Assuntos
Iodo , Glândula Tireoide , Lactoperoxidase/metabolismo , Lactoperoxidase/farmacologia , Acetilcarnitina/metabolismo , Acetilcarnitina/farmacologia , Peróxido de Hidrogênio/farmacologia , Iodo/química , Modelos Teóricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...